aerodynamic excitation

time varying loads acting on the blades of a fan due to nonconformities of the airflow. Note: spatial nonuniformities of airflow, which are steady in time, give rise to harmonic excitation at frequencies which are integer multiples of the rotation rate of the fan. Time excitations of the airflow give rise to random excitation. Turbulence of the airflow gives rise to random excitation.

air changes per hour (ACH)

ventilation airflow divided by room volume. It indicates how many times, during one hour, the air volume from a space is replaced with outdoor air.

air device

a diffuser, grille, register, or transfer grille used for controlling air patterns or air distribution or for preventing line of sight through an opening while allowing airflow through. See air terminal device or diffuser.

air distribution

transportation of a specified airflow to or from the treated space, by ducts or plenums. Air-treatment devices can be added to the distribution system for the purpose of treating the air (e.g., cleaning, heating, cooling, humidifying or dehumidifying, etc.)

air dumping

rapid falling of cold air that occurs when a variable-air volume (VAV) box or other device reduces airflow and the supply air leaves the diffuser at very low velocity.

air infiltration

the uncontrolled inward airflow through openings in the building envelope caused by the pressure effects of wind, the effect of differences in indoor and outdoor air density, or both (cfm) [m3/s].

air system balancing

adjusting airflow rates through air distribution system devices, such as fans and diffusers, by manually adjusting the position of dampers, splitter vanes, extractors, etc., or by using automatic control devices, such as constant-air-volume or variable-air-volume (VAV) boxes.

air terminal unit

(1) an air-distribution assembly consisting of inlet duct connection(s) and outlet duct connection(s) whose purpose fulfills (either manually or automatically) one or more of the following functions: controls the rate of the airflow, controls the velocity or pressure and/or temperature of the air, mixes primary streams of different temperatures or humidities, or mixes within the device primary air with air from the treated space. (2) an air terminal unit may be composed of automatic or manual dampers, filters valves, heating or cooling coils, sound attenuation, nozzles, or fan assemblies. See also diffuser terminal.

air/cloth ratio

value used in dust collector calculations to measure air velocity through the bag filter media. Note: calculated by dividing active volumetric airflow by the effective area of the cloth media.

air/media ratio

value used in dust collector calculations to measure air velocity through non-cloth bag filter media (e.g., paper cartridges). Note: calculated by dividing active volumetric airflow by the effective area of the cloth media.

airflow

(1) movement of air usually within boundaries (such as ducts). (2) the volume of air per unit time.

airflow rate (Q)

the volume of standard air per unit of time that moves past a given plane, expressed in cubic feet per minute (cfm) or liters per second (L/s).

airflow resistance

deterrent (due to friction, change of direction, etc.) to the passage of air within an air-distribution system and/or equipment.

airflow retarder

material or construction that adequately impedes transmission of air under specified conditions. Compare to structural barrier, water vapor retarder.

AK factor

the effective area of an air terminal device equal to the measured airflow rate divided by the velocity reading of a particular instrument used in a prescribed manner.

anemometer

device to sense and measure velocity of airflow at a point.

balancing

the methodical proportioning of air and hydronic flows through the system mains, branches, and terminal devices using acceptable procedures to achieve the specified airflow or hydronic flow within testing, design, and installation limitations.

balancing damper

adjustable blade device to control airflow.

building envelop leakage

overall leakage of the building characterized by the airflow rate at a given pressure difference across the envelope of the building. Compare to air infiltration).

burner register

series of air-directing vanes (usually adjustable) that are used to direct and/or control the combustion airflow through the burner.

bypass terminal

air terminal unit using a method of volume modulation whereby airflow is varied by distributing that volume required to meet the load, the balance of primary air being diverted to the return.

bypass terminal unit

a terminal unit, typically having more than one outlet, that uses a method of volume modulation whereby airflow is varied by distributing the volume required to meet the space requirements, the balance of supply/exhaust air being diverted away from the space.

ceiling cassettes

nonducted IDUs intended to be installed flush mounted with the ceiling. These IDUs can have configurations of indoor airflow coming from one, two, or four directions, or from a circular direction.

ceiling damper

device to protect air openings in fire-rated ceiling assemblies that operates to interrupt airflow automatically in the event of fire in order to restrict passage of heat and flame.

coil depth

the dimension of the finned surface as measured from the entering air face to the leaving air face in the direction of airflow.

compressibility coefficient

a thermodynamic factor that must be applied to determine fan total efficient from fan airflow rate, fan total pressure, and fan power input. It may be considered to be the ratio of the mean airflow rate through the fan to the airflow rate at fan air density. It is also the ratio of the fan total pressure that would be developed with an incompressible fluid to the fan total pressure that is developed with a compressible fluid.

cross ventilation

(1) natural ventilation in which the airflow mainly results from wind pressure effects on the building facades and where stack effects in the building are of less importance. (2) type of ventilating with air supply and exhaust points at opposite sides of ventilated space.

damper

element inserted into an air-distribution system or element of an air-distribution system permitting modification of the air resistance of the system and consequently changing the airflow rate or shutting off the airflow.

design airflow

required airflow when the system is operating under assumed maximum conditions of design, including diversity.

direct-injection humidifier

device that injects steam directly into the airflow.

discharge-loss coefficient

actual discharge airflow rate divided by the theoretical discharge airflow rate at a given pressure difference.

down-flow-type central furnace

one designed with airflow essentially in a vertical path, discharging air at or near the bottom of the furnace.

draft

(1) current of air, when referring to pressure difference that causes a current of air or gases to flow through a flue, chimney, heater, or space. (2) current of air, when referring to localized effect (generally, the unwanted local cooling of the body caused by air movement) caused by one or more factors of high air velocity, low ambient temperature, or direction of airflow whereby more heat is withdrawn from a person’s skin than is normally dissipated.

environmental systems

systems that primarily use a combination of mechanical equipment, airflow, water flow, and electrical energy to provide heating, ventilating, air conditioning, filtration, humidification, and dehumidification for the purpose of human comfort or process control of temperature and humidity.

exfiltration

(1) leakage of indoor air out of a building through similar types of openings. Like natural ventilation, it is driven by natural and/or artificial pressure differences. (2) uncontrolled outward air leakage from conditioned spaces through unintentional openings in ceilings, floors, and walls to unconditioned spaces or the outdoors caused by pressure differences across these openings due to wind, inside-outside temperature differences (stack effect), and imbalances between supply and exhaust airflow rates.

exhaust sound power level

sound power that is transmitted from an exhaust terminal inlet back to the room (counter to the airflow).

exhaust terminal unit

terminal unit for regulating exhaust or return airflow.

extract air

airflow leaving a treated space. Compare with return air.

face velocity

the rate of air movement at the face of the device (airflow rate divided by face area), expressed in m/s (fpm) to three significant figures.

fan

(1) a machine used to create flow within a fluid, typically a gas, such as air. (2) any device with two or more blades or vanes attached to a rotating shaft used to produce an airflow for the purpose of comfort, ventilation, exhaust, heating, cooling, or any other gaseous transport. The opening(s) may or may not have an element or elements for connection to ductwork. (3) fan consists of a rotating arrangement of vanes or blades that act on the air (impeller). Usually it is contained within some form of housing or case. This housing or case may direct the airflow or increase safety by preventing objects from contacting the fan blades. Most fans are powered by electric motors, but other sources of power may be used, including hydraulic motors and internal combustion engines. Fans produce airflows with high volume and low pressure, as opposed to compressors, which produce high pressures at a comparatively low volume. A fan blade will often rotate when exposed to an air stream, and devices that take advantage of this, such as anemometers and wind turbines, often have designs similar to that of a fan. (4) see also impeller.

fan airflow rate

the volumetric airflow rate at fan air density.

fan power output

the useful power delivered to air by the fan, it is proportional to the product of the fan airflow rate, the fan total pressure, and the compressibility coefficient.

filter-media velocity

the mean rate of air movement through the filter media (airflow divided by net effective filtering area). The term is not applicable to plate-type electronic air cleaners. Media velocity is measured in m/s (fpm).

final resistance

(1) the resistance at which a filter, or filter media, should be replaced. (2) the resistance to airflow of the air-cleaning device at which the test is terminated and results calculated, expressed in Pa (in. of water).

fire damper

device that interrupts airflow automatically through part of an air system to restrict passage of flame. Installed in a fire-rated wall or floor and closes automatically in the event of fire to maintain the integrity of the fire-rated separation.

flow

continuous motion of a fluid in pipes, ducts, channels, or through openings. See also airflow, backflow, slip.

flow equalizer

(1) a perforated plate installed downstream of a fan in an air-handling unit designed to diffuse airflow equally across a downstream coil. Also called a diffuser plate. (2) in a multiple cooling tower installation, a pipe installed below and interconnecting the cold basin of multiple cooling towers to equalize the basin water levels and prevent the sump suction in one tower from drawing air or creating a vortex. (3) in refrigeration, a line or lines installed between compressors to equalize oil levels. (4) the bypass pipe in a primary/secondary flow system that hydronically decouples the primary from the secondary pumping system. See cross connection.

freeze up

(1) failure of a refrigerating unit to operate normally due to formation of ice at the expansion device. (2) frost formation that impedes airflow through a coil.

gross sensible capacity

the rate of sensible heat removal by the cooling coil for a given set of operating conditions. This value varies as a function of performance parameters such as EWB, ODB, EDB, and airflow rate. (Also see sensible heat.)

gross total capacity

the total rate of both sensible heat and latent heat removal by the cooling coil for a given set of operating conditions. This value varies as a function of performance parameters such as EWB, ODB, EDB, and airflow rate. Also see sensible heat and latent heat.

HEPA Filter (Merv16+), ULPA, Particle Air Filter

product that uses only airflow through a medium to remove contaminants from the air.

induced air temperature

air temperature of the internally induced airflow. The mixed airstream resultant temperature of the mix of room air temperature stream with supply airstream.

induced airflow

air that is drawn into a terminal by means of induction and discharged through the terminal outlet

induced-draft water-cooling tower

type of mechanical draft tower in which one or more fans are located in the air outlet to induce airflow through the air inlets.

initial resistance

the pressure loss of the device operating at a specified airflow rate with no dust load, expressed in Pa (in. of water).

laminar flow

having airflow nominally in one direction.

lazy airflow

airflow within the fume hood is described as lazy when smoke remains on the work surface without smoothly flowing to the back baffle.

manual damper

device that can be used to manually adjust the airflow rate by manual operation. Also see damper, valve.

maximum outdoor air damper

a modulating damper or set of dampers used to control the outdoor airflow to the system in excess of minimum ventilation outdoor air for free cooling (airside economizer). Also called economizer outdoor air damper. May also serve to provide the minimum outside airflow control.

measurement station

element inserted in the ductwork that facilitates the determination of air temperature, air humidity, airflow rate, and/or pressure.

mixed flow fan

fan whose characteristics combine both centrifugal and axial airflow.

modulating diffuser terminal unit

diffuser with features of an air terminal unit and with an integral airflow control device.

natural draft

airflow resulting from the difference between atmospheric density and some lower density, chimney effect.

net effective filtering area

the total area in the device on which dust collects. For devices using fibrous media, it is the net upstream area of the media exposed to airflow measured in the plane or general surface of the media. Net effective area excludes the area blocked by sealants, flanges, or supports. In electronic air cleaners, it is the total exposed surface of those electrodes available for dust precipitation, including the ionizing section but excluding supports, holes, and insulators. Net effective filtering area is measured in m2 (ft2) to three significant figures.

net exhaust flow rate

the exhaust flow rate for a hood minus any internal discharge makeup airflow rate.

nonlaminar flow workstation

one without uniform airflow patterns and velocities.

outdoor air fraction

the outdoor air fraction is the ratio of the volumetric flow rate of outdoor air brought in by the air handler to the total supply airflow rate.

percent outdoor air

volumetric outside airflow rate expressed as a percentage of total supply airflow rate.

perfect mixing

a theoretical airflow distribution pattern within a ventilated space where the supply air is instantaneously and uniformly mixed with the air in the space such that the concentration of all constituents in the air, and the age of air, are spatially uniform.

plenum fan

fan assembly consisting of a single inlet impeller mounted perpendicular to airflow that pressurizes a plenum chamber in an air-distribution system. The impeller is typically an airfoil or backward-inclined design.

point of operation

the relative position on the cooling unit characteristic curve corresponding to a particular airflow rate. It is controlled during a test by adjusting the position of the throttling device, by changing flow nozzles or auxiliary fan characteristics, or by any combination of these.

pressure-dependent control system

control system in which the airflow through the air terminal varies with system pressure.

pressure-independent control system

control system in which the airflow through the air terminal is independent of system pressure. Also known as “pressure-compensated.”

primary air temperature

air temperature of the primary airflow (e.g., supply airflow from an air-handling unit).

qualification test

a procedure employed for verifying the accuracy of the measuring techniques (temperature, airflow rates, duct heat calibration) employed in determination of the room heating effect. This qualification procedure is periodically employed in determining the room heating effect.

rated airflow

the airflow rate in m3/s (cfm) at which the device is tested.

rated final resistance

the operating pressure loss at the airflow rate at which a disposable device (e.g., filter) should be replaced or renewed, as recommended by the manufacturer, expressed in Pa (in. of water).

reverse flow

airflow within the hood when smoke released in the hood moves forward, toward the front of the hood. This term does not apply to the forward motion of the roll inside the hood that occurs in the upper cavity of the hood above the hood opening or to the cyclonic motion that occurs behind a closed horizontal sash.

sampling tube

a tubular windscreen to be attached to a standard microphone and designed to minimize its sensitivity to airflow noise.

series fan-powered terminal

terminal where primary airflow is modulated and mixed with induced air by a continuously operated integral fan to provide a relatively constant volume of discharge.

single-duct unit

air-terminal unit assembly having one ducted air inlet and a device for regulating the airflow rate so it is independent of inlet pressure changes.

smoke control system

an engineered system that uses mechanical fans to produce airflows and pressure differences across barriers to limit smoke movement.

stack effect

(1) movement of air into and out of buildings, chimneys, flue gas stacks, or other containers and is driven by buoyancy. Buoyancy occurs due to a difference in indoor to outdoor air density resulting from temperature and moisture differences. The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect. The stack effect is also referred to as the chimney effect, and it helps drive natural ventilation and infiltration. (2) movement of air or other gas in a vertical enclosure (e.g., duct, chimney, building), induced by the density difference between the air or other gas in the enclosure and the ambient atmosphere. Note: stack effect is a significant concern in heating-system design for tall buildings in cold climates. Sometimes referred to as chimney effect. (3) pressure difference caused by the difference in density between indoor and outdoor air due to an indoor/outdoor temperature difference. (4) the vertical airflow within buildings caused by temperature differences between the building's interior and exterior.

static pressure loss

(1) external static pressure loss for forced-air systems using packaged air-handling equipment, the static pressure loss resulting from airflow through the supply and return ductwork and other elements external to the packaged air-handling unit. Compare to internal static pressure loss and total static pressure loss. (2) internal static pressure loss for forced-air systems, the static pressure loss resulting from airflow through the internal elements of the packaged air-handling unit. These internal elements may include such items as filters, coils, dampers, mixing sections, etc. Compare to internal static pressure loss and total static pressure loss. (3) total static pressure loss for forced-air systems, the sum of the external static pressure loss and the internal static pressure loss. See internal static pressure loss and external static pressure loss. The term is not applicable to an individual fan or a fan located within a builtup air-handling unit. Fans are rated by the term fan total static pressure, which is not the same as fan total pressure. Compare to fan total pressure.

stratified airflow

layers of air at different temperatures or different velocities flowing through a duct or plenum system and affect fan and/or pump performance in the distribution system.

structural barrier

vapor or gas seal integral to the structural materials of an enclosure. See water vapor retarder, airflow retarder.

supply air

(1) air delivered by mechanical or natural ventilation to a space, composed of any combination of outdoor air, recirculated air, or transfer air. (2) air entering a space from an air-conditioning, heating, or ventilating apparatus for the purpose of comfort conditioning. Supply air is generally filtered, fan forced, and either heated, cooled, humidified, or dehumidified as necessary to maintain specified conditions. Only the quantity of outdoor air within the supply airflow may be used as replacement air.

thermal anemometer

device that relies on the cooling effect of the airflow to change the temperature of a heated body in proportion to the air speed. Types include hot-wire anemometer, heated-bulb thermometer, heated-thermocouple anemometer, and heated-thermistor anemometer.

thermal plume

airflow created by a convective heat source that rises due to natural thermal buoyancy. Plume formation and growth are dependent on the intensity of the heat source and on the degree of stratification of the ambient air.

variable volume, variable temperature (VVT)

combination of varying both airflow and temperature in response to space load, for the purpose of resetting temperature to maintain greater low-load airflow to the space than in a true variable volume system.

variable-speed control of a fan

a method of controlling airflow produced by a fan by means of adjusting the speed or revolutions per minute (rpm) of the fan.

ventilation rate

rate of airflow to or from a space, expressed in terms of volume per unit of time, either through the ventilation system or infiltration through building envelope. These are commonly expressed as cubic feet per minute (CFM) in USCS units or liters per second (l/s) in SI units.

zone

(1) a separately controlled heated or cooled space. (2) one occupied space or several occupied spaces with similar occupancy category, occupant density, zone air distribution effectiveness, and zone primary airflow per unit area. (3) space or group of spaces within a building for which the heating, cooling, or lighting requirements are sufficiently similar that desired conditions can be maintained throughout by a single controlling device.